| pH: | |
| Range | -2.000 to 20.000 pH |
| Resolution | 0.1, 0.01, 0.001 pH |
| Accuracy | ± 0.002 pH |
| Calibration Points | Up to 7 |
| Standard Customization | Yes |
| Calibration Reminder | Yes |
| Standard Recognition | NIST,GB,DIN,USA,MERK,JIS buffers |
| Slope Limit | Yes |
| mV/ORP: | |
| Range | - 2000.00 to 2000.00 mV |
| Resolution | 0.1, 0.01 mV |
| Accuracy | ±0.1 mV or ±0.03 % of reading whichever is greater |
| EH ORP Mode | Yes |
| ORP Calibration Points | 1 custom point (relative mV) |
| pX: | |
| Range | - 2.000 to 20.000 pX |
| Resolution | 0.1, 0.01, 0.001 pX |
| Accuracy | ± 0.002 pX |
| Calibration Points | Up to 6 |
| ISE: | |
| Range | 1E-9 to 9.999E9 |
| Unit | mol/L, mmol/L, g/L, mg/L, μg/L, ppm |
| Resolution | Up to 4 significant digits |
| Accuracy | ± 0.3 % |
| Calibration Points | Up to 6 |
| Conductivity: | |
| Range | 0.000 μS/cm to 2000 mS/cm |
| Resolution | 1.01 Ωcm minimum |
| Reference Temperature | 5, 10, 15, 18, 20, 25 °C |
| Calibration Points | Up to 5 |
| Calibration Reminder | Yes |
| Standard Recognition | 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm; 12.88 mS/cm |
| Resistivity: | |
| Range | 5.00 Ωcm ~100.00 MΩcm |
| Accuracy | ± 0.5 % FS |
| TDS: | |
| Range | 0.000 ~1000 ppt |
| Resolution | 0.001 ppm minimum; changed with range |
| Accuracy | ± 0.5 % |
| Salinity: | |
| Type | NaCl % |
| Range | (0.00 ~8.00) % |
| Resolution | 0.01 % |
| Accuracy | ± 0.1 % |
| Dissolved Oxygen Concentration: | |
| Sensor Type | Polarographic |
| Range | 0.00 to 99.99 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy | ± 0.3 mg/L(0.00 to 20.00 mg/L)± 10%(20.00 to 99.99 mg/L) |
| Calibration Reminder | Yes |
| Calibration Points | Air-saturated water or zero point |
| Barometric Compensation | Yes |
| Manual Salinity Factor Correction | Yes |
| % Saturation: | |
| Range | (0.0 to 600)% |
| Resolution | 0.10 % |
| Accuracy | ± 10.0 % |
| Temperature: | |
| Range | - 10 to 135 °C, 14 to 275 °F |
| Unit | °C, °F |
| Resolution | 0.1 |
| Accuracy | ± 0.1 |
| Measurement: | |
| Reading Mode | AutoRead( Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked |
| Temp. Compensation | ATC, MTC |
| Data Management: | |
| Data Storage | 1000 Groups |
| GLP Features | Yes |
| Log Management | Yes |
| Inputs: | |
| pH Electrode | BNC(Q9) |
| Temp./DO Probe | 4-pin aviation connector |
| Temp./EC Probe | 5-pin aviation connector |
| Outputs: | |
| USB | USB 2.0 flash memory device, PC |
| RS 233 | printer,scanner,autosampler |
| Display Options: | |
| Backlight | Yes |
| Auto Shut-down | 1~60 min, off |
| IP Rating | IP54 |
| Date and Time | Yes |
| General: | |
| Power | AC Adapter, 100-240 V AC input, DC24V output |
| Dimensions | 220x195x68 mm |
| Weight | 950 g(2.09 lb) |
Download Catalog