| Optical Geometry | Transmittance: 0/D (parallel illumination, diffuse reflection receiving) |
| Standards compliant | ASTM D1003/1044, ISO 13468, ISO 14782, GB/T 2410, JJF 1303-2011, CIE 15.2, GB/T 3978, ASTM E308, JIS K7105, JIS K7361, JIS K 7136 |
| Integrating Sphere Size | Φ154mm |
| Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 |
| Spectral mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Measurement Wavelength range | 400 ~ 700 nm (wavelength can be customized) |
| Wavelength Pitch | 10 nm |
| Semi-bandwidth | 10 nm |
| Measuring range of transmittance | 0-100% |
| Measurement Aperture | Φ20 mm/Φ15 mm/Φ8 mm/Φ4 mm (select single aperture) |
| Sample thickness | less than 170 mm |
| color space | CIE LAB, XYZ, Yxy, LCh, s-RGB, βxy |
| Color Difference Formula | ΔEab, ΔE94, ΔEcmc (2:1), ΔEcmc (1:1), ΔE00 |
| Other Colorimetric data | Haze (ASTM D1003/1044, ISO 13468), Transmittance T (ISO), Transmittance T (ASTM), WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), Absorbance, Cobalt Platinum Index, Gardner Index |
| Observer | 2° / 10° |
| Displayed Data | Spectral graph, sample chromativity value, color difference value/graph, chromaticity graph, color simulation, pass/fail result |
| Measurement Time | About 1.5s |
| Measurement accuracy | 0.01 |
| Repeatability | Φ20 mm caliber, less than 0.08 (after the instrument is warmed up and corrected, test the standard deviation value of the standard deviation value of the standard haze sheet with a haze of about 30 is tested at an interval of 5s) |
| Inter-instrument agreement | Φ20mm,with 0.4 (After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) |
| Operating Environment | 0~40°C (32~104°F) |
| Storage Environment | -20~50°C (-4~122°F) |
| Battery Performance | DC 24V, 3A power adapter |
| Lamp life | 5 years, more than 30000000 times measurement |
| Display | 7 inch TFT capacity, Touchscreen display |
| Interface | USB, printing port, Bluetooth |
| Data Storage | 5,000 samples, 20,000 samples |
| Language | Chinese, English, traditional Chinese |
| Standard Accessories | Power adapter, user manual, quality management software (download), USB cable, 0% calibration box, measuring aperture |
| Optional Accessory | Mini printer, Test Fixture, Standard Haze Sheet, Footswitch |
| Size | 290x211x511 mm |
| Weight | About 7.6 kg |
Download Catalog